Welch Allyn SureBP Double Tube Blood Pressure Hose, 10 ft (3.0 m)
Welch Allyn
Blood Pressure Monitoring AccessoriesSureBP double-tube blood pressure hose for Connex and Spot Vital Signs monitors
Certifications
- Accessory intended to be used with Welch Allyn Connex and Spot Vital Signs NIBP monitors that are regulated medical devices.
- Listed by the manufacturer as latex Free (not made with natural rubber latex).
- Designed to meet applicable standards and regulatory requirements for non Invasive blood pressure accessories when used with compatible Welch Allyn systems.
- Accessory intended to be used with Welch Allyn Connex and Spot Vital Signs NIBP monitors that are regulated medical devices.
- Listed by the manufacturer as latex Free (not made with natural rubber latex).
- Designed to meet applicable standards and regulatory requirements for non Invasive blood pressure accessories when used with compatible Welch Allyn systems.
SureBP double-tube blood pressure hose for Connex and Spot Vital Signs monitors
Description
The Welch Allyn SureBP Double-Tube Blood Pressure Hose (part number 4500-31) is a 10 ft (3.0 m) non-invasive blood pressure (NIBP) hose designed to connect Welch Allyn SureBP cuffs to compatible devices such as the Connex Vital Signs Monitor, Connex Integrated Wall System and Spot Vital Signs / Spot Vital Signs LXi monitors. It is a dual-lumen, latex-free hose with dedicated connectors at each end, providing a reliable, extended-length connection between the monitor and adult or paediatric cuffs.
Bnefits
- Provides a 10 ft (3.0 m) extended length for flexible patient positioning and easier access during blood pressure measurement.
- SureBP double-tube design supports accurate, fast non-invasive blood pressure measurements with Welch Allyn monitors.
- Compatible with Connex Vital Signs Monitors, Connex Integrated Wall Systems and Spot Vital Signs/Spot Vital Signs LXi devices using SureBP technology.
- Latex-free construction reduces risk of latex-related allergic reactions for patients and clinicians.
- Dedicated monitor and cuff connectors simplify setup and minimise risk of incorrect connections.
- Durable medical-grade hose designed for repeated clinical use in hospitals, clinics and primary care settings.
- Dual-lumen configuration is optimised for adult and paediatric NIBP measurements when used with appropriate Welch Allyn cuffs.
- Standardised Welch Allyn part number (4500-31) makes replacement ordering and inventory management straightforward.
Indications
- Use as a non-invasive blood pressure (NIBP) hose to connect compatible Welch Allyn SureBP cuffs to Welch Allyn monitors.
- Intended for adult and paediatric NIBP measurements when used with suitable cuffs and devices.
- For use with compatible Welch Allyn Connex Vital Signs Monitors, Connex Integrated Wall Systems and Spot Vital Signs / Spot Vital Signs LXi monitors that accept the SureBP double-tube hose.
- Use in hospitals, clinics, emergency departments, outpatient practices and other professional healthcare environments where NIBP monitoring is required.
Composition
- Dual-lumen (double-tube) non-invasive blood pressure hose.
- Latex-free construction (not made with natural rubber latex).
- Medical-grade flexible tubing, typically PVC or similar polymer, suitable for repeated inflation/deflation cycles.
- Proximal connector: dedicated Welch Allyn device-end connector compatible with Connex and Spot Vital Signs family monitors.
- Distal connectors: dual cuff-end fittings designed to interface with Welch Allyn SureBP two-tube cuffs.
- Internal air channels designed to withstand repeated pressurisation within the device’s specified pressure range.
Formulation
- SureBP double-tube blood pressure hose.
- Nominal length: 10 ft (approximately 3.0 m).
- Designed for adult and paediatric non-invasive blood pressure monitoring.
- Accessory component for Welch Allyn Connex and Spot Vital Signs NIBP systems.
- Latex-free, non-sterile, reusable medical accessory.
- Configured as a dual-lumen hose with one device-end connector and two cuff-end connectors.
Packaging
- Supplied as a single (each) SureBP double-tube blood pressure hose.
- Individually packaged, labelled with manufacturer, brand, and part number 4500-31.
- May be supplied in multi-unit outer cartons for institutional purchasing.
- Packaging includes basic identification and traceability information for clinical inventory management.
Usage
- Before use, inspect the hose for visible damage, kinks, cracks or signs of wear. Do not use if any damage is observed.
- Identify the device-end connector and insert it firmly into the NIBP hose port of the compatible Welch Allyn monitor until it clicks or seats securely according to the monitor’s instructions for use.
- Attach the two cuff-end connectors to the corresponding ports on a compatible Welch Allyn SureBP double-tube cuff, ensuring secure, leak-free connections.
- Verify that the hose is routed without sharp bends, kinks or compression points that could obstruct airflow.
- Follow the instructions for use of the Welch Allyn monitor and cuff to position the cuff correctly on the patient and to initiate and complete NIBP measurements.
- After use, disconnect the hose by releasing the device-end connector according to the monitor’s instructions and uncoupling the cuff-end connectors from the blood pressure cuff.
- Clean and disinfect the hose between patients according to local infection-prevention policies and the manufacturer’s guidance for cleaning non-invasive blood pressure accessories (typically wiping with a suitable approved disinfectant; do not immerse unless explicitly permitted).
- Do not modify the hose or fit Luer-lock or other non-approved connectors to the tubing.
- Periodically re-inspect and replace the hose in accordance with facility policy or if any damage, stiffness, leakage or unreliable readings are observed.
Contraindications
- Do not use if the hose is visibly damaged, cracked, kinked, leaking or does not securely connect to the monitor or cuff.
- Do not use with non-compatible blood pressure monitors or cuffs that are not designed for Welch Allyn SureBP double-tube hoses.
- Do not fit Luer-lock or other invasive-line connectors to the hose, to avoid risk of misconnections to intravenous lines.
- Do not use for invasive blood pressure monitoring or any application involving direct vascular access.
- Do not use in environments or with cleaning agents that are incompatible with the hose materials as specified by the manufacturer.
Adverse Effects
- If misused or if the hose is kinked or compressed, the monitor may generate inaccurate blood pressure readings, potentially leading to clinical misinterpretation.
- Misconnection of blood pressure tubing to an intravenous line (if modified or used with non-approved connectors) could cause serious patient injury from inadvertent air or fluid injection.
- Prolonged cuff inflation due to blocked or damaged tubing could cause patient discomfort or, in extreme cases, limb injury.
- Allergic reactions to materials are unlikely due to latex-free construction but may occur in patients with sensitivities to other polymers or cleaning agents used on the hose.
Storage Conditions
- Store the hose in a clean, dry area away from direct sunlight and excessive heat or cold.
- Avoid storing the hose sharply bent, twisted or under heavy objects that could permanently kink or deform the tubing.
- Keep away from oils, solvents and harsh chemicals that could degrade the tubing material.
- When stored attached to a monitor or wall system, ensure the hose is loosely coiled or supported to prevent strain at the connectors.
- Follow any additional storage recommendations in the connected device’s instructions for use.
Duration
Not a therapeutic product; it is used only for the duration of each non-invasive blood pressure measurement and remains in service life-long subject to routine inspection and replacement policies.
Onset
Immediate; the hose transmits pressure changes as soon as a blood pressure measurement is initiated by the connected monitor.
| Price | Link |
|---|---|
| £103.19 | https://www.medisave.co.uk/products/blood-pressure-hose-10ft |
Browse more Blood Pressure Monitoring Accessories
ELI 150c Resting Electrocardiograph
Medisave
ELI 150c Resting Electrocardiograph
Medical and Aesthetic Equipment
- £4,822.79
- £4,078.79
- 5 more
MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes
Medisave
MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes
Medical and Aesthetic Equipment
- £25.99
- £28.99
- 7 more
ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug
Medisave
ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug
Medical and Aesthetic Equipment
- £3,091.19
- £2,762.39
- 3 more
Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4
Medisave
Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4
Medical and Aesthetic Equipment
- £736.79
- £571.19
- 3 more
Welch Allyn Comfort Sealing Eartips (Large, one pair)
Medisave
Welch Allyn Comfort Sealing Eartips (Large, one pair)
Medical and Aesthetic Equipment
- £5.49
- £35.99
- 2 more
Miller 00 Fiber Optic Laryngoscope Blade
Medisave
Miller 00 Fiber Optic Laryngoscope Blade
Medical and Aesthetic Equipment
- £206.39
- £206.39
- 2 more
ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE
Medisave
ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE
Medical and Aesthetic Equipment
- £87.59
- £257.99
- 2 more
GS777 Integrated Wall System, PanOptic, MacroView for CSM UK
Medisave
GS777 Integrated Wall System, PanOptic, MacroView for CSM UK
Medical and Aesthetic Equipment
- £2,279.99
- £2,243.99
- 0 more
ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug
Medisave
ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug
Medical and Aesthetic Equipment
- £1,689.59
- £1,919.99
- 0 more
ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)
Medisave
ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)
Medical and Aesthetic Equipment
- £46.79
- £56.39
- 1 more
ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets
Medisave
ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets
Medical and Aesthetic Equipment
- £32.39
- £14.39
- 1 more
Mobile Stand for Welch Allyn Vital Signs Monitor
Medisave
Mobile Stand for Welch Allyn Vital Signs Monitor
Medical and Aesthetic Equipment
- £148.79
- £140.35
- 1 more













